Table 1

Lung function prior to and 1, 2 and 6 months following endobronchial valve treatment for pneumatocele

Lung function—prior to and after treatment
Prior (2017)1 month2 months6 months
FVC, litres (% expected)4.8 (92)2.3 (45)3.2 (61)4.1 (80)
FEV1, litres (% expected)3.5 (83)1.8 (43)2.4 (59)3.2 (80)
DLCO (% expected)8.3 (77)4.0 (40)5.7 (57)7.1 (71)
  • DLCO, diffusing capacity for carbon monoxide; FEV1, forced expiratory volume in the first 1 s; FVC, forced vital capacity.