PT - JOURNAL ARTICLE AU - Giragani, Suresh AU - Balani, Ankit AU - Agrawal, Vikas TI - Stentriever thrombectomy with distal protection device for carotid free floating thrombus: a technical case report AID - 10.1136/bcr-2016-012904 DP - 2017 Jan 18 TA - BMJ Case Reports PG - bcr2016012904 VI - 2017 4099 - http://casereports.bmj.com/content/2017/bcr-2016-012904.short 4100 - http://casereports.bmj.com/content/2017/bcr-2016-012904.full AB - We report the clinical details, imaging findings and management of a 45-year-old man who presented with recurrent transient ischemic attacks due to carotid free floating thrombus. Free floating thrombus of the carotid artery is a very rare condition with a high risk of distal embolic shower. The optimal treatment options are debatable and include medical management, surgical thrombectomy and endovascular thrombectomy. We describe the use of a stentriever with filter protection in the management of carotid free floating thrombus as a novel treatment option.