Article Text

Download PDFPDF

Inadvertent inflation of Foley catheter balloon with contrast: an error that caused unnecessary apprehensions
Free
  1. Siddharth Pandey,
  2. Deepanshu Sharma,
  3. Gaurav Garg,
  4. Satyanarayan Sankhwar
  1. Department of Urology, King George’s Medical University, Lucknow, Uttar Pradesh, India
  1. Correspondence to Dr Siddharth Pandey, sid1420{at}gmail.com

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Description 

A 30-year-old male patient underwent percutaneous nephrolithotomy (PCNL) for a 3.5 cm right renal calculus. As per our institutional protocol he underwent a check X-ray the next day. The relatives of the patient immediately came to us asking whether some residual fragments of the calculus were there in the urinary bladder. When we reviewed the X-ray film, there was a radio-opaque shadow with a smooth contour in the region of urinary bladder. On careful examination this shadow was continuous with a radio-opaque line along the Foley catheter (figure 1). We immediately removed the Foley catheter and did another check X-ray. The shadow had disappeared. We then realised that the catheter’s balloon was inflated with contrast solution prepared for fluoroscopy-guided puncture during PCNL. We acknowledged this error to the patient and his relatives and explained them how sorry we were for their anxiety, following which they …