Statistics from Altmetric.com

Description

A 27-year-old man with history of mechanical aortic valve due to isolated congenital aortic valve stenosis presented with dyspnoea, orthopnea and fatigue for 2 weeks. On arrival, he was in atrial fibrillation with rapid ventricular response in the range of 150 bpm. Other vital signs were normal. His examination revealed diffuse rales but was otherwise unremarkable. His complete blood count (CBC), electrolytes, erythrocyte sedimentation rate (ESR), C reactive protein (CRP) and troponin-I were all normal. Brain natriuretic peptide (BNP) was 7580. International Normalized Ratio (INR) was subtherapeutic at 1.4; he was non-compliant with warfarin for 3 months due to insurance lapse. Chest X-ray revealed pulmonary vascular congestion, and he was treated using intravenous diuretics with good effect. Echo showed worsening cardiomyopathy with left ventricular ejection fraction (LVEF) 30%–35% (55% a year ago) and suspicion for a mass on his mechanical aortic valve suggestive of thrombus versus vegetation. Transesophageal echocardiogram (TEE) revealed 5 mm thrombus on mechanical aortic valve prosthesis with severely reduced anterior leaflet excursion (video 1). Cardiothoracic surgery was consulted and favoured medical management due to small size of thrombus. Fluoroscopy was performed in cardiac catheterisation laboratory, which showed immobile anterior aortic leaflet. Alteplase (tPA) was given, 1 mg per hour for 25 hours thorough peripheral intravenous line. This was followed by a 6-hour infusion of weight-based therapeutic unfractionated heparin (UFH). Re-fluoroscopy did not show any improvement in leaflet motion. Second dose of tPA (25 mg over 25 hours) followed by 6-hour UFH infusion was administered with no good results on fluoroscopy. Patient finally received third infusion of tPA which led to left arm bruising as well as swelling. Auscultation now revealed sharper sounding mechanical valve clicks. Repeat fluoroscopy confirmed much better valve movement with improved leaflet excursion (video 2). UFH was overlapped with warfarin until the goal INR (2.5–3.5) was achieved. Upper extremity bruising and swelling resolved spontaneously. He was fitted for a life vest given his depressed ejection fraction and risk of sudden cardiac death, medically optimised for his left ventricular (LV) dysfunction and discharged on warfarin with very close outpatient follow-up. Detailed discussion was undertaken regarding importance of medication adherence.

Mechanical aortic valve thrombosis is a rare but serious prosthesis complication. The annual rate of prosthetic mechanical valves ranges from 0.1% to 5.7% with even higher rate in patient not adherent to anticoagulation therapy.1 Diagnosis can be made by examination, TEE and fluoroscopy; we used the latter modality to assess tPA treatment effect.2 Treatment is either surgery or thrombolysis based on thrombus size and presence of obstruction.3 The major risk of fibrinolytic treatment is bleeding and systemic emboli, including stroke. Our case is unique in that we demonstrate safe use of three rounds of tPA. Fortunately, our patient did not have any immediate complications perhaps because of small thrombus size. We performed extensive education about compliance and planned for close follow-up to avoid future catastrophic events in this young patient.

Learning points

  • Treatment of mechanical valve thrombosis is either surgery or thrombolysis based on thrombus size and presence of obstruction.

  • Repeated attempts of thrombolysis are sometimes required to recover valvular function. Risk of bleeding and other complications needs to be weighed while making decision.

Video 1
Video 2

References

Footnotes

  • Contributors MAS wrote the main manuscript. MHSS designed and drafted the manuscript with main author. EJ edited the script. SP supervised and gave medical insights.

  • Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

  • Competing interests None declared.

  • Patient consent for publication Obtained.

  • Provenance and peer review Not commissioned; externally peer reviewed.

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.