Preoperative simulation unveiled undetected surgical difficulties in a case of cochlear implantation

BMJ Case Rep. 2017 Dec 2:2017:bcr2017222657. doi: 10.1136/bcr-2017-222657.

Abstract

We herein report a case in which extensive preparation changed a difficult-to-treat patient into an easy one. We performed a revision cochlear implantation on a patient whose first procedure had been aborted due to unidentified difficulties. During a series of thorough three-dimensional simulations, we found that the patient in question had a normal cochlea but the cochlea was placed in an unusual position and orientation. This condition is difficult to detect on standard preoperative radiographic images. Through this simulation, we were able to propose a surgical plan to avoid making the same mistakes as the first surgeon. We present this case not as a rare difficult case of an unfortunate patient but instead emphasise the importance of performing surgical simulation and looking for non-obvious difficulties. This case is an example of the success that can be achieved with such extensive preparation.

Keywords: ear, nose and throat/otolaryngology; otolaryngology / ent.

Publication types

  • Case Reports

MeSH terms

  • Child, Preschool
  • Cochlea / abnormalities*
  • Cochlea / surgery
  • Cochlear Implantation / adverse effects
  • Cochlear Implantation / methods*
  • Computer Simulation*
  • Female
  • Hearing Loss / congenital
  • Hearing Loss / surgery
  • Humans
  • Incidental Findings*
  • Preoperative Period
  • Reoperation / methods*