Rare complication of a percutaneous long line
Free
  1. Shiva Shankar1,
  2. Sagarika Ray2,
  3. Manish Gupta3
  1. 1Department of Neonatal Medicine, The Shrewsbury and Telford Hospital NHS Trust, Telford, UK
  2. 2Department of Neonatal Medicine, The Shrewsbury and Telford Hospital NHS Trust, Telford, UK
  3. 3Department of Paediatrics, The Shrewsbury and Telford Hospital NHS Trust, Telford, UK
  1. Correspondence to Dr Shiva Shankar, sshankar{at}nhs.net

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Description 

An infant of a diabetic mother required 20% glucose infusion for hypoglycaemia. This was initially administered via an umbilical venous catheter, which was subsequently dislodged. As the infant was over 24 hours old at the time, attempts at reinsertion of an umbilical venous catheter were not considered due the risk of infection. Consequently, the glucose infusion was administered through a percutaneous long line inserted in the left ankle. An abdominal radiograph revealed the tip to be at the level of L5 (figure 1). Eight hours following the start of the infusion, the left leg was noted to be pale, cool to touch and poorly perfused. The femoral pulse was weaker on that side with absence of the popliteal, posterior tibial and dorsalis pedis artery pulses. The long line was removed. The site of insertion of the long line was reinspected and noted to be posteroinferior to the medial malleolus.

Figure 1

Radiograph showing tip of the long line.

The vascular surgeons at a tertiary centre advised starting an intravenous heparin infusion prior to transfer. Following transfer to the tertiary centre, Doppler sonography showed a dampened waveform in the left superficial femoral artery and absence of any arterial thrombus. Perfusion returned to the left leg within a week despite continuing to have a weak femoral pulse and absent distal arterial pulses in that limb.

Percutaneous long lines inserted in the lower limbs should aim to have the tip ideally in the inferior vena cava. Long lines inserted in the left lower limb have the additional requirement to cross the midline at the level of L5 to ensure that the tip has traversed the left common iliac vein and not travelled up the left ascending lumbar vein. Malposition in the ascending lumbar vein is a recognised complication of long lines being inserted in the left lower limb. This should be suspected through typical radiographic signs such as any loop or bend in the course of the line which may occur due to the local anatomy in the left ileofemoral vein1 or tracking of radio-opaque dye alongside the left side of the spine in the anatomical position of the left ascending lumbar vein.2

The line tip in this infant may have been suspected to be in the ascending lumbar vein although it did not show all the typical radiographic signs. Moreover, arterial compromise of the left lower limb and the tip having not crossed the midline suggest that the tip of the long line may have been situated in the common iliac artery. This case illustrates the importance of having a strong suspicion of accidental insertion of a percutaneous long line into an artery if the tip does not cross the midline at the level of L5 and does not have any loop or bend or tracking of radio-opaque dye alongside the spine to indicate its malposition within the ascending lumbar vein.1 2 In such cases, it may be helpful to obtain a blood gas from the line to ascertain whether arterial or venous or evaluate with vascular ultrasound, if available.

Learning points

  • In the case of a percutaneous long line being inserted in the left lower limb, the tip at the level of L5 and to the left of the spine on a radiograph may not necessarily indicate its placement in a vein. In such cases, consider possible arterial cannulation and check for perfusion and pulses in that limb while considering removal of the line. Obtaining a blood gas from the line to check if it is arterial or evaluating with vascular ultrasound may be useful.

  • If there are signs of arterial compromise to the lower limb following insertion of a percutaneous long line, it is important to remove the line immediately, regardless of location.

References

View Abstract

Footnotes

  • Contributors SS identified the case and drafted the initial manuscript. SS and SR reviewed the manuscript. SS, SR and MG approved the final manuscript.

  • Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

  • Competing interests None declared.

  • Patient consent Parental/guardian consent obtained.

  • Provenance and peer review Not commissioned; externally peer reviewed.