Article Text
Summary
Negative pressure pulmonary oedema is well described in the literature as an uncommon but recognised complication of general anaesthe sia; negative pressure diffuse alveolar haemorrhage is a rarer consequence. We report a case of massive haemoptysis following elective general anaesthesia using a laryngeal mask airway device and sevoflurane anaesthetic maintenance. The patient had no obvious signs of laryngospasm or other cause of upper airway obstruction perioperatively. We explore the possibility that the haemoptysis was caused by clinically unapparent negative pressure generation, but also ask whether the anaesthetic agent should be considered as a culprit.
- anaesthesia
- respiratory system
- mechanical ventilation
Statistics from Altmetric.com
Footnotes
Contributors Case report discussed collaboratively, initial write-up by RM, edited and amended by CR.
Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.
Competing interests None declared.
Patient consent Obtained.
Provenance and peer review Not commissioned; externally peer reviewed.