Article Text

Download PDFPDF

A liver with a highly abnormal appearance
Free
  1. R A C Dimock1,
  2. P Ziprin2
  1. 1Accident and Emergency Department, North West London Hospitals, London, Middlesex, UK
  2. 2Academic Surgical Unit, Imperial College Healthcare NHS Trust, London, UK
  1. Correspondence to Dr Richard A C Dimock, richard.dimock{at}nhs.net

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Description

A 33-year-old man with Crohn's disease presented with 3 days of abdominal pain, bloody diarrhoea and vomiting. He was clinically stable and blood tests showed an isolated C reactive protein of 81. Ultrasound (US) scan showed a small air and fluid collection in the right iliac fossa and a highly abnormal liver architecture. An abdominal CT scan was performed (figures 1 and 2).

Figure 1

CT scan showing a distal ileal mass, local perforation and air within the venous system.

Figure 2

CT scan showing extensive air within the portal system of the liver to within 2 cm of the capsule.

This showed air within the portal venous system (hepatic portal venous gas, HPVG), tracking up the superior mesenteric vein from a distal ileal mass.

In HPVG the characteristic gas pattern extends to within 2 cm of the liver capsule, due to centrifugal blood flow,1 distinguishing it from pneumobilia, where the centripetal biliary flow results in gas collecting centrally. It is usually diagnosed on CT or US scan, although can occasionally be seen on plain film.

Causes include intestinal necrosis (43–70%), gastrointestinal dilation (9–12%), gastrointestinal inflammation (8–16%), sepsis (7–11%) and peptic-ulcer disease (4%).2 The mechanism is either (1) increased intraluminal pressure and mucosal damage, allowing gas to migrate into mural capillaries (as in this case) or (2) gas produced by gas-forming bacteria, either from pyelophlebitis in the portal system or from an abscess.

Although there is some evidence to suggest that HPVG can slow or even arrest portal flow, the finding of HVPG should be considered as a diagnostic clue and the underlying aetiology must be identified and treated. Mortality is quoted as 39%,3 rising to 75% in cases caused by bowel necrosis.

This patient underwent an open right hemicolectomy and end ileostomy and was discharged 8 days postoperatively.

Learning points

  • Hepatic portal venous gas (HPVG) is distinguished from pneumobilia by peripheral gas distribution, extending to within 2 cm of the liver capsule.

  • Bowel ischaemia is the most common cause with mortality of 75%.

  • HPVG is not a definitive indication for surgery and management should be directed by the cause; however, an early laparotomy is often needed.

Acknowledgments

The authors would like to acknowledge Mr Paul Ziprin.

References

View Abstract

Footnotes

  • Competing interests None.

  • Patient consent None.

  • Provenance and peer review Not commissioned; externally peer reviewed.