Severe intimal hyperplasia after sirolimus eluting stent deployment: evaluation by optical coherence tomography
Free
  1. R Gupta,
  2. O C Raffel,
  3. I-K Jang
  1. ijang{at}partners.org

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

A 60-year-old man presented with recurrence of angina and a positive stress test five months following sirolimus-eluting stent deployment to the left anterior descending (LAD) and intermediate (ramus) coronary arteries.

Coronary angiography revealed severe focal in-stent restenosis of both the previously stented arteries (panel A: LAD restenosis marked by arrow). The LAD lesion was pre-dilated with a 2.5 mm×10 mm cutting balloon. Following this, optical coherence tomography (OCT, LightLab Imaging Inc, Westford, Massachusetts, USA) and intravascular ultrasound (IVUS) were performed. OCT images at the site of stenosis clearly revealed severe focal intimal proliferation surrounding a well expanded stent (panel B: OCT image showing marked neointimal proliferation. Cuts made by the cutting balloon are well demonstrated (arrowheads) and struts of the previous stent (arrows) are clearly seen, making accurate assessment of stent expansion possible). Corresponding IVUS images, while showing the stenosis, were unable to sufficiently visualise the neointimal proliferation or the adequacy of previous stent expansion (panel C). OCT imaging was also able to accurately define the length of the segment with significant neointimal formation. A 3.0 mm × 12 mm paclitaxel-eluting stent was deployed across the LAD restenosis with an excellent angiographic result.

OCT is a light based imaging technology that provides detailed images with a resolution of 10 μm. In this case OCT was able to provide important information on the aetiology and extent of the LAD re-stenosis. OCT may prove to be an important tool to help guide percutaneous coronary interventions in the future.

Acknowledgments

This article is reproduced with permission from Gupta R, Raffel O C, Jang I-K. Severe intimal hyperplasia after sirolimus eluting stent deployment: evaluation by optical coherence tomography Heart 2007;93:754